Home Products Ozone Destruct Filter

ozone-destruction-catalyst-bh1
ozone-destruction-catalyst-bh2
ozone-destruction-catalyst-bh1
ozone-destruction-catalyst-bh2

Ozone Destruction Filter (GTODC-BH)


GTODC-BH filter is made of activated carbon mesh filled with ozone decomposition catalyst. The size of the ozone filter can be customized according to needs, and the installation is convenient and flexible, mainly for the purification of low-concentration ozone emissions. It can quickly catalyze and decompose ozone into non-toxic oxygen at room temperature.


Technical Parameters

Appearance Black honeycomb flake Applicable Humidity ≤90%
Product size Customization (Thickness 10-50mm) Applicable Airspeed
10,000-50,000 h-1
Supports Material The shell is activated carbon filter, and the inside is filled with GTODC-GC catalyst Working Temperature ≥70 °F
Coating Material Nano composite metal oxide Purification efficiency 95-99.9%
Bulk Density
300-500 kg/m3
Purification Depth 0.1 ppm
Specific Surface Area
≥800 m2/g
Service Life 1-3 years
Suitable O3 Concentration ≤500 ppm Product Packaging Bag or Barrel

Advantage

1, Easy Installed

GTODC-BH filter uses activated carbon mesh to wrap the GTODC-GC catalyst to form a monolithic honeycomb structure, which is easy to install and suitable for use in air purifiers.

2, Firm Surface Coating

The carrier with high specific surface area is loaded with highly dispersed nano active sites, the catalytic decomposition efficiency of ozone is higher, and the ozone is instantly converted into oxygen at room temperature.

3, High Catalytic Activity

The catalyst adopts a composite multi-element catalyst system. After years of technical research and use verification, the catalyst has high catalytic activity and high stability.

4, High moisture Resistance

The coating of the ozone catalyst adopts rare earth composite oxide with high catalytic activity, which has a stable structure and can resist high humidity.


Precautions

1, Catalyst Installation

When the ozone destruction catalyst is used in the reactor, the minimum thickness of the catalyst layer is 50mm, the gas pipe does not flow shortly and the air is leaked, and all the gas passes through the catalyst layer.

2, Particle Filtration

Before the exhaust gas enters the catalyst layer, it is necessary to filter the particulate matter to avoid long-term accumulation of dust on the catalyst and cause the catalyst to fail.

3, Catalytic Temperature

The catalyst can catalyze the decomposition of ozone into oxygen at room temperature. Appropriate heating can help increase the rate of catalytic reaction. The effect is better when used at (40~80℃).

4, Restore Catalytic Activity

After the catalyst has been used for a certain period of time (for example, about one year), if the activity of the catalyst is found to be reduced due to the long-term accumulation of adsorbed moisture, the catalyst can be taken out, dried in an oven at 100°C for 6 hours or more, and then reloaded for use.


Use Scenes

1, Decomposition of ozone tail gas from ozone generator.

2, Decomposition of ozone produced by corona treatment, plasma treatment or uv-curing etc.

3, Space ozone eliminating of copier & printer, medical equipment, aircraft cabin, etc.

4, Ozone Removal in Industrial Waste Gas Emissions.